ID 110603
| Weighting factor for acceleration of distance control for lowering movement exceeds maximum permissible value. | ||||
| Description | The acceleration (P-AXIS-00416) used for the lowering movement of the distance control [FCT-M3] can be weighted with the factor P-AXIS-00534 in per mille [0.1%]. However, the given weighting factor is greater than permissible. | |||
| Response | Class | 1 | Warning, weighting factor for acceleration P-AXIS-00534 is corrected. | |
| Solution | Class | 1 | Correct parameter P-AXIS-00534. | |
| Parameter | %1: | Logical axis number [-] | ||
| Logical axis number P-AXIS-00016 of axis affected | ||||
| %2: | Error value [0.1%] | |||
| Invalid weighting value P-AXIS-00534 | ||||
| %3: | Upper limit value [0.1%] | |||
| Maximum permissible acceleration weighting P-AXIS-00534 | ||||
| %4: | Corrected value [0.1%] | |||
| Corrected value for acceleration weighting P-AXIS-00534 | ||||
| Error type | 2, Error message by data transfer from parameter list into control device. | |||
| 
 | ||||