CNC objects
For further information on addressing CNC objects, see [FCT-C13//Description].
Activating filter rules
| Name | cnc_error_filter_w | |||
| Description | The individual filter rules of the platform can be activated and deactivated via the GUI by setting the applicable bitmask. This is dependent on the parameters defined in P-STUP-00188. Therefore, up to 32 different filter rules can be switched. Example of the assigned filter definition: 
 | |||
| Task | COM (Port 553) | |||
| Index group | 0x120100 | Index offset | 0x26C | |
| Data type | UNS32 | Length | 4 | |
| Attributes | write | Unit | - | |
| Remarks | See Error filter definition in start-up list | |||
| Name | mc_error_filter_w | |||
| Description | The individual filter rules of a channel can be activated and deactivated via the GUI by setting the applicable bitmask. This is dependent on the parameters defined in P-CHAN-00380. Therefore, up to 32 different filter rules can be switched. Example of the assigned filter definition: 
 | |||
| Task | COM (Port 553) | |||
| Index group | 0x12010<CID> | Index offset | 0x419 | |
| Data type | UNS32 | Length | 4 | |
| Attributes | write | Unit | - | |
| Remarks | 
 | |||
| Name | ac_<AID>_error_filter_w | |||
| Description | The individual filter rules of an axis can be activated and deactivated via the GUI by setting the applicable bitmask. This is dependent on the parameters defined in P-AXIS-00629. Therefore, up to 32 different filter rules can be switched. Example of the assigned filter definition: 
 | |||
| Task | COM (Port 553) | |||
| Index group | 0x120200 | Index offset | 0x<AID>0028 | |
| Data type | UNS32 | Length | 4 | |
| Attributes | write | Unit | - | |
| Remarks | 
 | |||
Access to logging mode
| Name | cnc_error_manager_mode_r | |||
| Description | CNC object to read the error management mode. See P-STUP-00167. | |||
| Task | COM (Port 553) | |||
| Index group | 0x120100 | Index offset | 0x293 | |
| Data type | UN32 | Length/byte | 4 | |
| Attributes | read | Unit | - | |
| Remarks | The assignments and meanings of the bits are described in the table. | |||
| Name | cnc_error_manager_mode_w | |||
| Description | CNC object to write the error management mode. See P-STUP-00167. | |||
| Task | COM (Port 553) | |||
| Index group | 0x120100 | Index offset | 0x26D | |
| Data type | UN32 | Length/byte | 4 | |
| Attributes | write | Unit | - | |
| Remarks | The assignments and meanings of the bits are described in the table. | |||
| Identifier | Bit assignment | Meaning | 
|---|---|---|
| FILTER_OFF | 0x00004 | No filters are evaluated | 
| VERBOSE | 0x00008 | Extended internal diagnostics | 
| WITHOUT_ERROR_MANAGER | 0x00001 | Direct output without error management | 
| 
 | 
 | 
 | 
| 0x00010 | Execute print output | |
| LOG | 0x00020 | Log output to log file | 
| REPORT | 0x00040 | Log output to log file | 
| SEND_TO_PLC_NONE | 0x20000 | Suppress output to the PLC | 
| 
 | 
 | 
 | 
| PRINT_EXTENDED | 0x00100 | Extended print output | 
| LOG_EXTENDED | 0x00200 | Extended log output | 
| REPORT_EXTENDED | 0x00400 | Extended application-specific output | 
| 
 | 
 | 
 | 
| PRINT_NO_WARNINGS | 0x01000 | Warnings are suppressed in the print output | 
| LOG_NO_WARNINGS | 0x02000 | Warnings are suppressed in the log output | 
| REPORT_NO_WARNINGS | 0x04000 | Warnings are suppressed in the report output | 
| SEND_TO_PLC_NO_WARNINGS | 0x08000 | Suppress warnings to PLC | 
| STARTUP_NO_WARNINGS | 0x10000 | Suppress warnings during controller start-up | 
| NO_WARNINGS | 0x1f000 | Suppress all warnings | 
| TC3_EVENT_LOGGER | 0x80000 | Output to TC3 Event Logger | 
| Name | log errors | ||
| Description | This object defines whether CNC error messages are output to the PLC:  | ||
| Task | GEO (Port 551) | ||
| Index group | 0x120300 | Index offset | 0x4 | 
| Data type | BOOLEAN | Length | 1 | 
| Attributes | read/ write | Unit | [-] | 
| Remarks | Values : TRUE/FALSE | ||