Description
| P-AXIS-00568 | Damping factor of natural frequency | |
| Description | Besides the natural frequency itself, this parameter can also specify the damping factor of the natural frequency which is defined as follows: 
 
 | |
| Parameter | vib_guard.damping | |
| Data type | REAL64 | |
| Data range | 0 ≤ damping ≤ 1 | |
| Axis types | T, R, S | |
| Dimension | T: ---- | R,S: ---- | 
| Default value | 0.1 | |
| Drive types | ---- | |
| Remarks | The parameter is available as of V3.1.3075.00 | |
| P-AXIS-00571 | Vibration Guard mode | |
| Description | This parameter defines Modes 1 - 4 of the Vibration Guard function. 
 Modes 1– 3: 
 Mode 4: 
 
 | |
| Parameter | vib_guard.mode | |
| Data type | UNS32 | |
| Data range | 1 ≤ mode ≤ 4 | |
| Axis types | T, R, S | |
| Dimension | T: ---- | R,S: ---- | 
| Default value | 1 | |
| Drive types | ---- | |
| Remarks | See Table of sensitivity to natural frequency: The parameter is available as of V3.1.3075.00 | |
| P-AXIS-00588 | Activating the Vibration Guard | |
| Description | This parameter can permanently activate or deactivate the Vibration Guard function at program start. | |
| Parameter | vib_guard.active | |
| Data type | BOOLEAN | |
| Data range | 0/1 | |
| Axis types | T, R, S | |
| Dimension | T: ---- | R,S: ---- | 
| Default value | 0 | |
| Drive types | ---- | |
| Remarks | Alternatively, the Vibration Guard can also be activated or deactivated by the NC command #VIB GUARD / OFF . The parameter is available as of V3.1.3075.00 | |
| P-AXIS-00589 | Machine natural frequency | |
| Description | This parameter specifies the machine’s natural frequency which the Vibration Guard function is to suppress. | |
| Parameter | vib_guard.freq | |
| Data type | REAL64 | |
| Data range | 1 ≤ freq | |
| Axis types | T, R, S | |
| Dimension | T: Hz | R,S: Hz | 
| Default value | 30 | |
| Drive types | ---- | |
| Remarks | The parameter is available as of V3.1.3075.00 | |