ID 150104
| Inadmissible value for handwheel counter address (P-MANU-00004). | ||||
| Description | The manual mode parameters are read and interpreted by the CNC. 
 The CNC detects that a value for manual mode parameters P-MANU-00004 exceeds the CNC system internal limit. 
 Parameter P-MANU-00004 indicates the address to which the handwheel counters are sent to the CNC. When this message is displayed, the high-level interface to the PLC was defined as the transfer location (see P-MANU-00003). The HLI interface selected to transfer the handwheel counter reading is defined in parameter P-MANU-00004 . | |||
| Response | Class | 3 | Manual mode parameters are not transferred to the CNC. | |
| Solution | Class | 6 | Correct the value for P-MANU-00004,  Reinterpret manual mode parameters by restarting CNC system. | |
| Parameter | %1: | Current value [-] | ||
| Index of interface to transfer handwheel counter reading to CNC defined in manual mode parameter data record. | ||||
| %2: | Limit value [-] | |||
| Maximal allowed index value. | ||||
| %3: | Logical identifier of control element [-] | |||
| Identifier of logical control element whose parameters caused the message. | ||||
| Error type | 2, Error message on data transfer of parameter lists to controller. | |||
| 
 | ||||