ID 110617
| Process data element for the 'probing_command_start' signal was not found in the cyclic process data. | ||||
| Description | When configuring the SERCOS real-time control bits for the signal 'Command start probing', the process data element configured in P-AXIS-00699 was not found in the configured cyclic process data. | |||
| Response | Class | 1 | An error message is output containing the axis parameters P-AXIS-00118 (measurement axis) and P-AXIS-00098 (kasto_achse) are reset in order to prevent the execution of measurement run or edge banding with incompletely configured probes. | |
| Solution | Class | 1 | Correct P-AXIS-00699. | |
| Parameter | %1: | 
 | ||
| Log. axis number | ||||
| %2: | 
 | |||
| Incorrect value of P-AXIS-00699 | ||||
| %3: | 
 | |||
| Drive type | ||||
| Error type | 2, Error message on data transfer of parameter lists to controller. | |||
| 
 | ||||