ID 110610
| The process data for the 'probe_actuated' signal was not found in the cyclic process data. | ||||
| Description | When configuring the SERCOS realtime status bits for the signal 'measuring probe ½' actuated', the process data element configured in P-AXIS-00679 (probe 1) or P-AXIS-00685 was not found in the configured cyclic process data. | |||
| Response | Class | 1 | Output of an error message containing the axis parameters P-AXIS-00118 (measurement axis) and P-AXIS-00098 (kasto_achse) are reset, in order to prevent the execution of measurement run or edge bending with incompletely configured probes. | |
| Solution | Class | 1 | P-AXIS-00679/ or P-AXIS-00685 must be corrected. | |
| Parameter | %1: | 
 | ||
| Log. Axis number | ||||
| %2: | 
 | |||
| Incorrect value of P-AXIS-00679/or P-AXIS-00685 | ||||
| %3: | 
 | |||
| Drive type | ||||
| Error type | 2, Error message by data transfer from parameter list into control device. | |||
| 
 | ||||