ID 110602
| Weighting factor for velocity of distance control for lowering movement exceeds maximum permissible value. | ||||
| Description | The velocity (P-AXIS-00415) used for the lowering movement of the distance control (see FCT-M3) can be weighted with the parameter P-AXIS-00533 in per mille [0.1%]. However, the specified weighting factor is greater than permissible. | |||
| Response | Class | 1 | Warning, weighting factor for velocity P-AXIS-00533 is corrected. | |
| Solution | Class | 1 | Correct parameter P-AXIS-00533. | |
| Parameter | %1: | Logical axis number [-] | ||
| Logical axis number P-AXIS-00016 of axis affected | ||||
| %2: | Incorrect value [0.1%] | |||
| Invalid weighting value P-AXIS-00533 | ||||
| %3: | Upper limit value [0.1%] | |||
| Maximum permissible velocity weighting P-AXIS-00533 | ||||
| %4: | Corrected value [0.1%] | |||
| Corrected value for velocity weighting P-AXIS-00533 | ||||
| Error type | 2, Error message on data transfer of parameter lists to controller. | |||
| 
 | ||||