ID 110524
| Modulo range exceeds data range because of resolution settings. | ||||
| Description | Modulo range defined through the parameters P-AXIS-00127 and P-AXIS-00126 was exceeded. This is caused by a change in distance resolution. This is set via parameters P-AXIS-00234 and P-AXIS-00233. | |||
| Response | Class | 3 | None | |
| Solution | Class | 7 | Check and modify the modulo limits and the parameters of distance resolution. | |
| Parameter | %1: | Logical axis number [-] | ||
| Log. axis number P-AXIS-00016 | ||||
| %2: | Current value [-] | |||
| %3: | Limit value [-] | |||
| Maximum possible value for P-AXIS-00126 with constant distance resolution | ||||
| %4: | Current value [-] | |||
| %5: | Limit value [-] | |||
| Minimum possible value for P-AXIS-00127 with constant distance resolution | ||||
| Error type | 2, Error message on data transfer of parameter lists to controller. | |||
| 
 | ||||