ID 70394
| Maximum admissible distance for homing exceeded. | ||||
| Description | During homing, the axis has moved further than the permissible distance set in parameter P-AXIS-00412 from the start position of homing. This is an indication that the homing sequence is disturbed, e. g. the reference cam was not found. | |||
| Response | Class | 7 | Abort program, output error message. | |
| Solution | Class | 6 | Remove reason for homing fault. | |
| Parameter | %1: | Logical axis number [-] | ||
| 
 | ||||
| %2: | Limit value [0.1 µm or 0.0001°] | |||
| Set value of P-AXIS-00412. | ||||
| %3: | Error value [0.1 µm or 0.0001°] | |||
| Distance from start position of homing. | ||||
| %4: | Current value [-] | |||
| Current command position. | ||||
| %5: | Current value [0.1 µm or 0.0001°] | |||
| Modulo range of the axis. | ||||
| Error type | 1, Error message from NC program. | |||
| 
 | ||||