ID 70370
| Setting homing position not possible because fieldbus does not deliver valid data. | ||||
| Description | The command to set the homing position was sent via the HLI; however, the fieldbus did not supply any valid position actual values for the axis. Setting the homing position is not possible in this situation. 
 See Adopting the homing position [HLI// Section: MCControlBoolUnit_SetReferencePosition] for CNC build < 2800 [HLI// Section: lr_mc_control.set_reference_position] for CNC Build > 2800 | |||
| Response | Class | 7 | Stop axis. | |
| Solution | Class | 6 | Set homing position only if actual values valid for the axis are supplied by the fieldbus. | |
| Parameter | %1: | Logical axis number [-] | ||
| Log. axis number of the axis (see also P-AXIS-00016). | ||||
| %2: | Current value [-] | |||
| Flag indicates if fieldbus delivers valid actual positions. | ||||
| Error type | - | |||
| 
 | ||||