ID 70250
| Invalid resolution of master axis for cross compensation. | ||||
| Description | The compensation values for cross compensation were specified in increments in the corresponding compensation value list. This is only permitted for a measuring system path resolution of one (see P-AXIS-00234, P-AXIS-00233). However, the master axis whose position affects the slave axis uses a path resolution unequal to one. 
 See: | |||
| Response | Class | 7 | Controlled slave axis stop. And disable compensation for the slave axis | |
| Solution | Class | 7 | Change the value of parameter P-COMP-00003 in the compensation value list to one and enter the compensation values metrically (in 0.1 µm). | |
| Parameter | %1: | Logical axis number [-] | ||
| Logical axis number of the slave axis P-AXIS-00016 | ||||
| %2: | Logical axis number [-] | |||
| Logical axis number of affected master axis, see P-AXIS-00016, P-COMP-00005 | ||||
| %3: | Error value [-] | |||
| Path resolution of measuring system of slave axis, see P-AXIS-00233, P-AXIS-00234 | ||||
| %4: | Expected value[-] ] | |||
| Expected path resolution of the measuring system see P-AXIS-00233, P-AXIS-00234 | ||||
| Error type | 11, Error message from position controller. | |||
| 
 | ||||