ID 50663
| Given filter time constant is invalid. | ||||
| Description | The specified filter time constant P-AXIS-00357 is smaller or larger than permissible. The filter coefficients can therefore not be calculated. Permissible values are (where TAb = cycle time of the NC controller): 
 TAb ≤ P-AXIS-00357 ≤ MAX(UNS32) 
 For time delay filters: 0 ≤ P-AXIS-00357 < 6 * TAb | |||
| Response | Class | 3 | The filter is deactivated. | |
| Solution | Class | 7 | Correct parameter P-AXIS-00357 | |
| Parameter | %1: | Logical axis number [-] | ||
| Logical axis number P-AXIS-00016 of axis affected | ||||
| %2: | Current value [-] | |||
| Number of filter affected | ||||
| %3: | Current value [-] | |||
| Filter type P-AXIS-00204 | ||||
| %4: | Current value [µs] | |||
| Invalid time constant P-AXIS-00357 | ||||
| %5: | Upper limit value [µs] | |||
| Maximum permissible time constant P-AXIS-00357 | ||||
| Error type | - | |||
| 
 | ||||