ID 50557
| Characteristic filter frequency greater than half the sampling rate. | ||||
| Description | According to Shannon's sampling theorem, the maximum cut-off frequency is (½*TA= cycle time of the NC controller). The cut-off frequency of the PT1 filter is calculated from the time constant as follows: fg = 1 / (2 * PI * P-AXIS-00357). The cut-off frequency of all other filters is specified directly in the parameter P-AXIS-00067. 
 Possible solutions: Reduce cut-off frequency P-AXIS-00067. Increase the time constant P-AXIS-00357 for PT1 filters. Reduce the cycle time of the NC controller 
 | |||
| Response | Class | 3 | The filter is deactivated. | |
| Solution | Class | 7 | Reduce the cut-off frequency P-AXIS-00067 or increase the time constant P-AXIS-00357 | |
| Parameter | %1: | 
 | ||
| Logical axis number P-AXIS-00016 of axis affected | ||||
| %2: | 
 | |||
| Number of filter affected | ||||
| %3: | 
 | |||
| Filter type P-AXIS-00204 | ||||
| %4: | 
 | |||
| Current filter cut-off frequency P-AXIS-00067 | ||||
| %5: | 
 | |||
| Sampling frequency of the controller (1 / TA) | ||||
| Error type | - | |||
| 
 | ||||