Tolerance band for limits (P-AXIS-00421)

P-AXIS-00421

Tolerance band for limits

Description

This parameter defines a minimum distance from the minimum and maximum sensor positions.

If this distance is undershot, the CNC generates the error messages ID 70330 or ID 70576. If the tolerance band is specified by zero, the limits of the minimum and maximum sensor positions from the axis parameters P-AXIS-00419 and P-AXIS-00420 have a direct effect.

Parameter

kenngr.dist_ctrl[i].tolerance (where i=0)

Data type

SGN32

Data range

0 ≤ tolerance < MAX(SGN32)

Axis types

T, R

Dimension

T: 0.1µm

R: 0.0001 °

Default value

0

Drive types

SERCOS, Profidrive, CANopen

Remarks

Available as of Build V3.1.3080.12 or V3.1.3107.44

For compatibility reasons, the parameters

kenngr.distc.tolerance and

kenngr.distc.toleranz

continue to be available.