Upper limit for measuring system (P-AXIS-00419)

P-AXIS-00419

Upper limit for measuring system (spindle with touch probe)

Description

The following parameter defines the upper limit of the sensor. An error message is generated if it is exceeded while distance control is active.

Parameter

kenngr.distc.max_pos

Data type

SGN32

Data range

0 ≤ max_pos < MAX(SGN32)

Axis types

T, R

Dimension

T: 0.1 µm

R: 0.0001°

Default value

50000

Drive types

SERCOS, Profidrive, CANopen