Upper limit for measuring system (P-AXIS-00419)

P-AXIS-00419

Upper limit for measuring system

Description

The parameter defines the upper limit of the sensor. An error message is output if this limit is exceeded when distance control is active.

Parameter

kenngr.dist_ctrl[i].max_pos (where i=0)

Data type

SGN32

Data range

0 ≤ max_pos < MAX(SGN32)

Axis types

T, R

Dimension

T: 0.1µm

R: 0.0001 °

Default value

50000

Drive types

SERCOS, Profidrive, CANopen

Remarks

Available as of Build V3.1.3080.12 or V3.1.3107.44

For compatibility reasons, the parameter