Home gantry slave axis relative to encoder overflow (P-AXIS-00393)
| P-AXIS-00393 | Home gantry slave axis relative to encoder overflow | |
| Description | When this parameter is set to 1, a gantry slave axis is homed with the following method: At the moment when the master axis position is set, the offset of the slave axis relative to the encoder overflow is determined and the slave axis position is set to P-AXIS-00152 + 'distance to encoder overflow'. No homing movement takes place for this axis. The mechanical axis position of the slave axis can be shifted by P-AXIS-00354 . | |
| Parameter | kenngr.gantry_slave_relative_homing | |
| Data type | BOOLEAN | |
| Data range | 0/1 | |
| Axis types | T, R, S | |
| Dimension | T: ---- | R,S: ---- | 
| Default value | 0 | |
| Drive types | ---- | |
| Remarks | This parameter can only be used if the following conditions are fulfilled: 
 If these conditions are not fulfilled, the machine may be damaged! | |