Number of position control cycles (P-AXIS-00332)
| P-AXIS-00332 | Number of position control cycles during movement to a fixed stop | |
| Description | This parameter defines the number of position control cycles for the waiting time after exceeding the specified position lag limit P-AXIS-00331 before the measured value is determined. If the limit is again exceeded after this time, counting starts from the beginning. | |
| Parameter | kenngr.fixed_stop_nbr_cycles | |
| Data type | UNS16 | |
| Data range | 0 < fixed_stop_nbr_cycles < MAX(UNS16) | |
| Axis types | T, R | |
| Dimension | T: Number of interpolation cycles | R: Number of interpolation cycles | 
| Default value | 0 | |
| Drive types | Conventional, SERCOS, Terminal, Lightbus, Profidrive, CANopen | |
| Remarks | 
 | |