Limit for position lag (P-AXIS-00331)
| P-AXIS-00331 | Limit for position lag during movement to a fixed stop | |
| Description | This parameter specifies the limit for the position lag. After exceeding this limit, the fixed stop is detected and the measuring position is taken over. | |
| Parameter | kenngr.fixed_stop_pos_lag_limit | |
| Data type | UNS32 | |
| Data range | 0 ≤ fixed_stop_pos_lag_limit ≤ MAX(UNS32) | |
| Axis types | T, R | |
| Dimension | T: 0.1 µm | R: 0.0001° | 
| Default value | 0 | |
| Drive types | Conventional, SERCOS, Terminal, Lightbus, Profidrive, CANopen | |
| Remarks | 
 | |