Element name (P-AXIS-00426)

P-AXIS-00426

Element name of signal 'Drive is referenced' during reference monitoring

Description

In this parameter enter the name of the element of the cyclic input process data which is used for transmission of the signal 'Drive is referenced' from the drive.

When the set-up value of P-AXIS-00426 is not found within the cyclic process, the error message P-ERR-70401 is output.

Parameter

antr.reference_check.element_name

Data type

STRING

Data range

<Empty string>: Reference monitoring is disabled

S-0-0135: When the SERCOS state word is used for transmission of the reference signal, the parameter has to be set to 'S-0-0135'…

<Telegram_element_Name>: ...or, alternatively, the name of a telegram element configured in the cyclic process data.

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

*

Drive types

SERCOS

Remarks

* Note: The default value of variables is a blank string.

Reference monitoring is activated by assigning a value to this parameter. When reference monitoring is activated, the parameter P-AXIS-00425 must also be assigned a valid value.

At the moment, this parameter is supported for drive type SERCOS only.

Changing this parameter by a list update is not possible (P-ERR-110550).