ID 110700

Parameter for writing reference position P-AXIS-00584 invalid.

Description

The parameter P-AXIS-00584 (kenngr.write_reference_position_to_drive) is used to write the homing position from P-AXIS-00152 to the drive before drive-controlled homing.

The value specified for the parameter P-AXIS-00584 is invalid.

Response

Class

1

Warning message output and deactivate function.

Solution

Class

1

Check and modify the settings in P-AXIS-00584

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of axis affected

%2:

Error value [-]

Incorrect value for P-AXIS-00584

%3:

Upper limit value[-]

Permissible maximum value for P-AXIS-00584

%4:

Corrected value [-]

Corrected value for P-AXIS-00584

Error type

2, Error message by data transfer from parameter list into control device.