ID 110700
Parameter for writing reference position P-AXIS-00584 invalid. | ||||
Description | The parameter P-AXIS-00584 (kenngr.write_reference_position_to_drive) is used to write the homing position from P-AXIS-00152 to the drive before drive-controlled homing. The value specified for the parameter P-AXIS-00584 is invalid. | |||
Response | Class | 1 | Warning message output and deactivate function. | |
Solution | Class | 1 | Check and modify the settings in P-AXIS-00584 | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number P-AXIS-00016 of axis affected | ||||
%2: | Error value [-] | |||
Incorrect value for P-AXIS-00584 | ||||
%3: | Upper limit value[-] | |||
Permissible maximum value for P-AXIS-00584 | ||||
%4: | Corrected value [-] | |||
Corrected value for P-AXIS-00584 | ||||
Error type | 2, Error message by data transfer from parameter list into control device. | |||
|