Minimum permissible output value (P-AXIS-00725)

P-AXIS-00725

Minimum permissible output value

Description

By this parameter the minimum permissible output value can be defined. If the value specified in the configuration lists or in the NC program undershoots the set limit, it is automatically limited to the minimum value. Thereby no error message is created.

If P-AXIS-00725 is configured, P-AXIS-00726 must be greater than this parameter, otherwise the warning P-ERR-70385 is output and the values are exchanged.

No value limit takes place by default.

Irrespective of this parameter setting, a value range check always takes place with the specified data type P-AXIS-00722. If an overflow is detected, the controller outputs the error message P-ERR-70384.

Parameter

antr.fixed_stop.drive_ident[i].min_limit

Data type

REAL64

Data range

Dependent on P-AXIS-00722 and P-AXIS-00724

Axis types

T, R

Dimension

T: ----

R: ----

Default value

1.000000e+199, no limit takes place.

Drive types

SERCOS, CANopen

Remarks

By default no limit is active; the limit is disabled at a value of 1.000000e+199.