State of “delete distance to go”

Delete distance to go, state

Description

The signal “delete distance to go active” is set as long as the NC block is executed. If one DEL DIST2GO motion is interrupted by a following DEL DIST2GO command, the status signal remains set during the entire short cut.

The signal is reset after the short cut NC blocks were executed.

CNC Build

< V2.11.2800

>= V2.11.2800

Information flow

CNC → SPS

ST path

pMC[idx]^.addr^.StateBahn_Data.

X_DeleteDistanceToGoActive

gpCh[idx]^.bahn_state.

delete_distance_to_go_active_r

Data type

BOOL

Access

PLC reading