Allow already actuated probes when starting a measurement run (P-CHAN-00312)

P-CHAN-00312

Allow already-actuated measuring probes when starting a measurement run

Description

When this parameter is initialised with 0 (default value), an error message is generated when a measurement run is started with a measuring probe that has already been actuated. The measurement run is cancelled and the CNC assumes the error state.

When this parameter is initialised with 1 and the measuring probe is already actuated, the measurement run is ended immediately and without error.

Parameter

meas_allow_actuated_probe

Data type

BOOLEAN

Data range

0: Actuated probe is not allowed at the start of the measurement run (default).

1: Actuated probe is allowed at the start of the measurement run.

Dimension

----

Default value

0

Remarks