Allow already actuated probes when starting a measurement run (P-CHAN-00312)
P-CHAN-00312 | Allow already-actuated measuring probes when starting a measurement run |
Description | When this parameter is initialised with 0 (default value), an error message is generated when a measurement run is started with a measuring probe that has already been actuated. The measurement run is cancelled and the CNC assumes the error state. When this parameter is initialised with 1 and the measuring probe is already actuated, the measurement run is ended immediately and without error. |
Parameter | meas_allow_actuated_probe |
Data type | BOOLEAN |
Data range | 0: Actuated probe is not allowed at the start of the measurement run (default). 1: Actuated probe is allowed at the start of the measurement run. |
Dimension | ---- |
Default value | 0 |
Remarks |
|