Distance resolution of measurement system (numerator, P-AXIS-00234)

P-AXIS-00234

Distance resolution of measurement (numerator)

Description

The path resolution of the measuring system is input in the dimension [increment/0.1 µm] for translatory axes or [increment/0.0001°] for rotational axes. The number of increments must be entered into 'getriebe[i].wegaufz' (numerator) and the size of the traverse path into 'getriebe[i].wegaufn' (denominator), in [0.1µm] for translatory axes or in [0.0001°] for rotatory axes.

Parameter

getriebe[i].wegaufz

Data type

UNS32

Data range

1 ≤ wegaufz ≤ MAX(UNS32)

Axis types

T, R, S

Dimension

T: Increments

R,S: Increments

Default value

1

Drive types

----

Remarks

These entries are not taken over when the axis parameters list is actualized, to change them a reboot is necessary.

Note that when the resolution factor is greater than 1, the moving range is restricted to less than (-MAX(UNS32)… +MAX(UNS32)) [µm/10-³ °].