Distance resolution of measurement system (numerator, P-AXIS-00234)
P-AXIS-00234 | Distance resolution of measurement (numerator) | |
Description | The path resolution of the measuring system is input in the dimension [increment/0.1 µm] for translatory axes or [increment/0.0001°] for rotational axes. The number of increments must be entered into 'getriebe[i].wegaufz' (numerator) and the size of the traverse path into 'getriebe[i].wegaufn' (denominator), in [0.1µm] for translatory axes or in [0.0001°] for rotatory axes. | |
Parameter | getriebe[i].wegaufz | |
Data type | UNS32 | |
Data range | 1 ≤ wegaufz ≤ MAX(UNS32) | |
Axis types | T, R, S | |
Dimension | T: Increments | R,S: Increments |
Default value | 1 | |
Drive types | ---- | |
Remarks | These entries are not taken over when the axis parameters list is actualized, to change them a reboot is necessary. Note that when the resolution factor is greater than 1, the moving range is restricted to less than (-MAX(UNS32)… +MAX(UNS32)) [µm/10-³ °]. If wegaufz is 0, the CNC generates the warning 110386 and corrects the parameter to the value 1. |