Defining the functionalities for path preparation (P-STUP-00060)
P-STUP-00060/ | Defining functionalities for path preparation. | |
Description | This parameter defines the individual functionalities for path preparation. The individual functions can be enabled or disabled for testing or for performance reasons. | |
Parameter | configuration.channel[i].path_preparation.function | |
Data type | STRING | |
Data range | FCT_DEFAULT | The functions FCT_FFM | FCT_PRESEGMENTATION | FCT_SPLINE | FCT_POLY | FCT_CAX | FCT_CAX_TRACK | FCT_SEGMENTATION are available. |
FCT_FFM | Free-form surface mode, #HSC [OPMODE 1 CONTERR 0.01], #HSC [OPMODE 2] | |
FCT_PRESEGMENTATION | Linear pre-segmentation in HSC mode | |
FCT_SPLINE | #HSC[], AKIMA, B-Spline, G150/G151 | |
FCT_POLY | #CONTOUR MODE[], G61, G261/G260 | |
FCT_CAX | C axis processing, i.e. the spindle is embedded in the NC channel. | |
FCT_CAX_TRACK | #CAX TRACK, tracking an axis according to the contour angle | |
FCT_SEGMENTATION | For dynamic segmentation of the path contour, e.g. if the curvature of a polynomial segment varies significantly. | |
The following functions must also be enabled: | ||
FCT_LIFT_UP | Automatic lifting/lowering of an axis (path-based coupling). | |
FCT_EMF | Edge machining (sharp angle contours). | |
FCT_EMF_POLY_OFF | Edge machining inactive with polynomials. Contrary to the setting with FCT_EMF, edge signal generation is masked when path polynomial generation is active in the channel. Polynomials are generated for smoothing G261 or when BSpline is active. The resulting geometry is then tangential. Example: FCT_DEFAULT | FCT_EMF_POLY_OFF |
| FCT_SYNC | Synchronise an axis to a path group. |
FCT_PRECON | Optimised planning using #HSC[BSPLINE]. | |
FCT_LIFT_UP_TIME | Automatic lifting/lowering of an axis (time-based coupling). | |
FCT_PTP | Dynamically optimised smoothing of the complete contour. | |
| FCT_M_PRE_OUTPUT | Pre-output of M/H functions (microwebs). |
FCT_SURFACE | HSC machining with Surface Optimiser | |
FCT_SEG_CHECK | Block segmentation in combination with path-controlled offset of M functions (dwell time), see P-STUP-00070 | |
Dimension | ---- | |
Default value | FCT_DEFAULT | |
Remarks |
|