Conditional filter activation (P-AXIS-00631)

P-AXIS-00631

Conditional filter activation (filtering of axis error messages)

Description

The individual error identifiers can be listed as numbers of texts and the entire line must comply with the following syntax:

( number | text ) {, ( number | text ) }

 

where:

number:= CNC error number

text:=" error-specific text "

 

Parameter

error_filter[i].conditional_param
where i = 0 ... 3 (maximum number of filters, application-specific)

Data type

STRING

Data range

Maximum of 96 characters

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

*

Remarks

Configuration example:

error_filter[0].conditional.param "D012:", 123, 1001

 

Individual error texts are currently only checked when the SERCOS drive error S95 is read out.

Error numbers are checked only in the case of SERCOS drive errors (S21 and S22) and in the case of ProfiDrive drive errors (parameter 945).