Setting of Parameter 1 (P-AXIS-00145)
P-AXIS-00145 | Setting parameter 1 for measurement simulation | ||||
Description | Depending on the method selected, the measurement simulation requires meas_simu_mode (P-AXIS-00112) a predefined value (axis position, part distance, counter value) as command condition to generate the measurement signal. This predefined value is stored in this parameter in the corresponding unit. | ||||
Parameter | meas_simu.parameter1 | ||||
Data type | SGN32 | ||||
Data range | MIN(SGN32) ≤ parameter1≤ MAX(SGN32) | ||||
Axis types | T, R | ||||
Dimension | T: ---- | R,S: ---- | |||
Default value | 0 | ||||
Drive types | Simulation | ||||
Remarks | Unit of parameter 1 dependent on the selected mode: | ||||
meas_simu_mode - Wert | 1 | 2 | 3 | ||
parameter1 - unit | 0.1µm or 0.0001° | ------- | % |