Setting of Parameter 1 (P-AXIS-00145)

P-AXIS-00145

Setting parameter 1 for measurement simulation

Description

Depending on the method selected, the measurement simulation requires meas_simu_mode (P-AXIS-00112) a predefined value (axis position, part distance, counter value) as command condition to generate the measurement signal.

This predefined value is stored in this parameter in the corresponding unit.

Parameter

meas_simu.parameter1

Data type

SGN32

Data range

MIN(SGN32) ≤ parameter1≤ MAX(SGN32)

Axis types

T, R

Dimension

T: ----

R,S: ----

Default value

0

Drive types

Simulation

Remarks

Unit of parameter 1 dependent on the selected mode:

meas_simu_mode - Wert

1

2

3

parameter1 - unit

0.1µm or 0.0001°

-------

%