Maximum deceleration (P-AXIS-00541)

P-AXIS-00541

Maximum delay for manual operation without parallel interpolation

Description

The parameter defines the maximum delay for manual operation. When the parameter has the value 0, the value of P-AXIS-00009 (handbetrieb.hba_max) is used.

Parameter

handbetrieb.hb.d_max

Data type

UNS32

Data range

0 < d_max ≤ P-AXIS-00008

Axis types

T, R

Dimension

T: mm/s²

R: °/s²

Default value

0

Drive types

----