Maximum permissible output value (P-AXIS-00409)

P-AXIS-00409

Maximum permissible output value

Description

By this parameter the maximum permissible output value can be defined. If the programmed value of the #DRIVE command exceeds the maximum value, the drive output value is set automatically on the maximum value. Thereby no error message is created.

If the parameter is greater than the greatest possible output value of the data type, defined by P-AXIS-00399 the error message P-ERR-70383 is output and the value of the parameter is corrected.

If P-AXIS-00408 is configured, P-AXIS-00408 must be smaller than this parameter. If this is not the case, the warning P-ERR-70385 is output and the minimum and maximum values are exchanged.

If this parameter is not configured, no limitation is active.

Parameter

antr.function[i].max_limit

Data type

REAL64

Data range

This is dependent on P-AXIS-00399 and P-AXIS-00401

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

1.000000e+199

Drive types

SERCOS, Profidrive, CANopen

Remarks