Value of data element after start-up of control (P-AXIS-00400)

P-AXIS-00400

Value of data element after start-up of control

Description

This parameter defines the value of the cyclic telegram element after start-up of the control.

Parameter

antr.function[i].startup_value

Data type

REAL64

Data range

If P-AXIS-00399 = 'SGN16':

MIN(SGN16) ≤ startup_value ≤ MAX(SGN16)

 

If P-AXIS-00399 = 'SGN32':

MIN(SGN32) ≤ startup_value ≤ MAX(SGN32)

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

0

Drive types

SERCOS, Profidrive, CANopen

Remarks

This parameter is only used if P-AXIS-00397 has the value 'CYCLIC'.