Element name of additional information for calculation of HLI signal 'power_state_e' (P-AXIS-00711)

P-AXIS-00711

Element name of additional information for calculation of HLI signal 'power_state_r'

Description

This parameter is set to the name of the element of the cyclic process data which is used to transfer the 'Ready for Power'-signal from the drive.

When the set-up value of P-AXIS-00711 is not found within the cyclic process, the error message P-ERR-70499 is output.

Parameters

antr.add_ready_for_operation.element_name

Data type

STRING

Data range

When no value is configured, the additional 'Ready for Power'-signal is not calculated and is not taken into account in the calculation of the 'power_state_r'-on the HLI.

S-0-0135: When the SERCOS state word is used for transmission of the reference signal, the parameter has to be assigned the value 'S-0-0135' or ...

<Telegram_element_Name>: ...otherwise the name of a telegram element configured in the cyclic process data.

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

Drive types

Simulation, SERCOS, Profidrive, CANopen, Terminal

Remarks

The additional 'Ready for Power’ test is activated when a value is assigned to this parameter. When reference monitoring is activated, the parameter P-AXIS-00709 must also be assigned a valid value.