Time base for normalisation of velocity (P-AXIS-00207)

P-AXIS-00207

Time base for normalisation of velocity

Description

The time base for adaptation of velocity interface to used unit in drive can be given as value per minute, second or sample interval. If the normalising per sample interval is selected, the output value changes proportional depending on CNC cycle time with constant velocity. This can be essential depending on drive.

Parameter

antr.v_time_base

Data type

UNS16

Data range

0: per minute

1: per second

2: per sample interval

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

0

Drive types

SERCOS