Sign reversal of command value (P-AXIS-00231)

P-AXIS-00231

Sign reversal of command value

Description

This parameter defines the sign reversal of command value.

Parameter

lr_hw[i].vz_stellgr

Data type

BOOLEAN

Data range

0/1

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

0

Drive types

Simulation, Conventional, Terminal, Lightbus, Profidrive

Remarks

These entries are not taken over when the axis parameters list is updated. To change them, a reboot is required.