Tolerance band for limits (P-AXIS-00421)

P-AXIS-00421

Tolerance band for limits (spindle with touch probe)

Description

Recording of actual values always returns changing values. By means of the tolerance band, values are also permissible that might lie outside the configured limits without an error message being generated.

Parameter

kenngr.distc.tolerance

Data type

SGN32

Data range

0 ≤ tolerance < MAX(SGN32)

Axis types

T, R

Dimension

T: 0.1µm

R: 0.0001°

Default value

0

Drive types

SERCOS, Profidrive, CANopen

Remarks