Maximum permissible correction value (P-AXIS-00525)

P-AXIS-00525

Maximum permissible correction value (volumetric compensation)

Description

This parameter defines the maximum permissible correction value which can be included by the volumetric compensation in the axis. If this limit is exceeded, an error message is generated and the axis is stopped in a controlled way.

This parameter should be configured for all cartesian axes (including gantry slaves), involved in a volumetric compensation. Otherwise during start-up a warning is output.

Parameter

lr_param.vol_comp.s_limit

Data type

REAL64

Data range

0 ≤ s_limit < MAX(REAL64)

Axis types

T

Dimension

T: 0.1µm

 

Default value

0

Drive types

----

Remarks