Definition of traverse distance between lubrication pulses (P-AXIS-00237)

P-AXIS-00237

Definition of traverse distance between lubrication pulses

Description

This parameter is used for testing an exceeding of a traverse distance.

In case the axis has, since the last lubrication pulse, once again covered the traverse distance defined by the parameter, the message 'triggering of lubrication pulse' is given out in the form of a PDU. If in the machine axis data set no distance (wsi_meldung = 0) is specified, then no PDU is given out.

Parameter

getriebe[i].wsi_meldung

Data type

SGN32

Data range

0 ≤ wsi_meldung ≤ MAX(UNS32)

Axis types

T, R, S

Dimension

T: mm

R: °(degree)

S: Revolutions

Default value

0

Drive types

----

Remarks

The resolution between the positions and WSI-units is determined through the following constants, which the user can still adapt. The following default settings are valid :

Axis type

Specified in

Constant

Value

T

mm

WSI_AUFLOESUNG_TRANSLATOR

10000 [0.1µm / mm]

R

° (degree)

WSI_AUFLOESUNG_ROTATOR

10000 [0.0001° / °]

SPINDLE

Rev.

WSI_AUFLOESUNG_SPINDEL

10000/360 [0.0001° / U]