Reinitialisation of additional position interface on enable (P-AXIS-00499)
P-AXIS-00499 | Reinitialisation of additional position interface on enable | |
Description | With the additional command position interface additional position command values can be commanded to an axis from the PLC via the HLI (see [HLI]). These additional values are passed as absolute values via the HLI and are output to the axis if the interface is active. When the value in that interface is changed while it is disabled, that change becomes efficient the next time the interface is activated, which can cause unexpected axis movements. With this parameter it can be set up that changes in the additional position interface while the interface is disabled do not cause an axis movement on reactivation, but only changes while the interface is enabled. | |
Parameter | kenngr.in_add_interface_init_on_enable | |
Data type | BOOLEAN | |
Data range | 0/1 | |
Axis types | T, R, S | |
Dimension | T: ---- | R,S: ---- |
Default value | 0 | |
Drive types | ---- | |
Remarks |
|