Reduced maximum speed with active G00 (P-AXIS-00155)

P-AXIS-00155

Reduced maximum speed with active G00

Description

When G00 is active, and with control signal REDUCED_SPEED, the PLC can command a switchover to a reduced axis rapid feed the CNC. The CNC reacts in real time. After an eventually necessary deceleration none of the axes moves faster than the parameter entry.

Parameter

getriebe[i].rapid_speed_red

Data type

UNS32

Data range

0 ≤ rapid_speed_red ≤ P-AXIS-00212

Axis types

T, R, S

Dimension

T: µm/s

R,S: 0.001°/s

Default value

0

Drive types

----

Remarks

 

Reduced maximum speed with active G00
Reduced maximum speed with active G00