Average value filter for current master velocity (P-AXIS-00300)

P-AXIS-00300

Average value filter for current master velocity for camming / gearing

Description

Arithmetic average value filter for current master velocity on (1) / off (0). This parameter is used for gearing with the current master velocity.

Parameter

cam_gear.mv_type

Data type

UNS16

Data range

0/1

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

0

Drive types

----

Remarks