Minimum time in tolerance range for speed synchronisation (P-AXIS-00290)

P-AXIS-00290

Minimum time in tolerance range for speed synchronisation for camming / gearing

Description

Time the axis has to be in the tolerance range defined in P-AXIS-00289 until it is considered speed synchronous.

Parameter

cam_gear.time_in_window

Data type

UNS32

Data range

0 ... MAX(UNS32)

Axis types

T, R, S

Dimension

T: µs

R,S: µs

Default value

8000

Drive types

----

Remarks