Actuation time delay of measuring switch (P-AXIS-00487)

P-AXIS-00487

Actuation time delay of measuring switch

Description

This parameter sets the actuation time delay of the measuring switch. When the probe is actuated, the CNC corrects the measured position to compensate the actuation time delay of the switch. The axis velocity during measurement is considered to be constant. Velocity changes due to acceleration or deceleration processes are not accounted for.

Parameter

kenngr.probe_actuation_time_delay

Data type

UNS32

Data range

0 ≤ probe_actuation_time_delay ≤ MAX(UNS32)

Axis types

T, R, S

Dimension

T: µs

R,S: µs

Default value

0

Drive types

----

Remarks