Bit number of process data element 'start measurement command' (P-AXIS-00700)

P-AXIS-00700

Bit number of process data element 'start measurement command'

Description

This parameter defines which bit in the process data element configured in P-AXIS-00699 is used to transfer the bit to start the measurement command to the drive.

The last significant bit has number 0, the maximum value depends on the used process data.

When the SERCOS control word is used for transmission of the 'start measurement command''-bit, only bit numbers 6 and 7 can be used (real-time control bits 1 and 2).

Parameter

antr.sercos.probing_command_start.bit_nr

Data type

SGN16

Data range

-1 … MAX(SGN16)

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

-1

Drive types

SERCOS

Remarks