Bit number process data 'probe 2 actuated' (P-AXIS-00686)

P-AXIS-00686

Bit number process data 'probe 2 actuated'

Description

This parameter defines which bit of the process data set up in P-AXIS-00685 is used to transfer the information that probe 2 is actuated.

The last significant bit has number 0, the maximum value depends on the used process data.

When the SERCOS status word is used for transmission of the 'probe 2 actuated' bit, only bit numbers 6 and 7 can be used (real-time status bits 1 and 2).

Parameter

antr.sercos.probe_2_realtime_bits.probe_actuated.bit_nr

Data type

SGN16

Data range

-1 … MAX(SGN16)

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

-1

Drive types

SERCOS

Remarks

When the configured bit number is invalid, error message P-ERR-110611 is output and the axis parameters P-AXIS-00118 (measuring axis) and P-AXIS-00098 (kasto_axis) are reset in order to prevent the execution of probing or edge banding with incompletely configured probes.