Name process data 'probe 2 actuated' (P-AXIS-00685)

P-AXIS-00685

Name process data 'probe 2 actuated'

Description

This parameter defines, in which cyclic process data the drive signals in a bit that probe 2 is actuated.

When one of the real-time status bits of the SERCOS status is used this parameter has to be set to 'S-0-0135' or 'S_0_135', in all other cases to the name of the process data in the process data configuration.

When this parameter is used, the number of the bit used for transmission has to be entered in P-AXIS-00686.

Parameter

antr.sercos.probe_2_realtime_bits.probe_actuated.element_name

Data type

STRING

Data range

-

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

-

Drive types

SERCOS

Remarks

When this parameter is not found in the process data configuration error message P-ERR-110610 is output and the axis parameters P-AXIS-00118 (measuring axis) and P-AXIS-00098 (kasto_axis) are reset in order to prevent the execution of probing or edge banding with incompletely configured probes.