Name process data 'enable probe 2' (P-AXIS-00681)

P-AXIS-00681

Name process data 'enable probe 2'

Description

This parameter defines the bit that is transferred to a specific cyclical process data element to enable probe 2 to drive SERCOS drives.

When one of the real-time control bits of the SERCOS control word is used, this parameter has to be set to 'S-0-0134' or 'S_0_0134' and in all other cases to the name of the process data element in the process data configuration.

When this parameter is used, the number of the bit used for transmission has to be entered in P-AXIS-00682.

Parameter

antr.sercos.probe_2_realtime_bits.start_probing.element_name

Data type

STRING

Data range

-

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

-

Drive types

SERCOS

Remarks

When this parameter is not found in the process data configuration error message P-ERR-110612 is output and the axis parameters P-AXIS-00118 (measuring axis) and P-AXIS-00098 (kasto_axis) are reset in order to prevent the execution of probing or edge banding with incompletely configured probes.