Bit number process data 'enable probe 1' (P-AXIS-00676)

P-AXIS-00676

Bit number process data 'enable probe 1'

Description

This parameter defines, which bit in the process data configured with P-AXIS-00675 is used to transfer the 'enable probe 1' bit to the drive.

The last significant bit has number 0, the maximum value depends on the used process data.

When the SERCOS control word is used for transmission of the 'enable probe 1' bit, only bit numbers 6 and 7 can be used (real-time control bits 1 and 2).

Parameter

antr.sercos.probe_1_realtime_bits.start_probing.bit_nr

Data type

SGN16

Data range

-1 … MAX(SGN16)

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

-1

Drive types

SERCOS

Remarks

When the configured bit number is invalid, error message P-ERR-110613 is output and the axis parameters P-AXIS-00118 (measuring axis) and P-AXIS-00098 (kasto_axis) are reset in order to prevent the execution of probing or edge banding with incompletely configured probes.