Number of probing input (P-AXIS-00517)

P-AXIS-00517

Number of probing input

Description

The parameter defines the measuring channel, which is used during a measuring traverse. When the DRIVE measuring signal is set (see P-AXIS-00516) the selected measuring channel must also be parametrised in the drive (see @@[FCT-C4]).

This parameter replaces the old setting antr.probing_input_nbr (P-AXIS-00430).

Parameter

kenngr.measure.input

Data type

UNS08

Data range

Valid measuring inputs dependent on drive type and measuring signal (see table below):

Measuring signal

P-AXIS-00516

Drive type

P-AXIS-00018

Measuring input

PLC_EXT_LATCH_CONTROL

all

1 to 255

DRIVE

SERCOS

CANopen

PROFIDRIVE MC

1 to 2

Conventional

Beckhoff Lightbus

+-10V via field bus

Real-time (RT)-Ethernet

CAN-Bus

1

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

0 **

Drive types

----

Remarks

*All measuring signals which are not shown above do not use the parameter 'Input' for the measuring channel!

**If P-AXIS-00517 is not specified, the CNC uses the old setting from the parameter P-AXIS-00430 due to backward compatibility.