ID 70636
| Timestamp could not be assigned to the distributed clocks times. | ||||
| Description | An interpolation is made between two cycles to calculate the position of the drive when a measuring event occurs. For this purpose, the high-resolution timestamp of the digital input terminal must be assigned to the Distributed Clocks times in the cycles before and after the timestamp. An error occurred on assigning the timestamp. | |||
| Response | Class | 7 | Controlled halt of the axis, the control loop is closed. | |
| Solution | Class | 7 | Check whether Distributed Clocks is active in the fieldbus. Resynchronise Distributed Clocks. | |
| Parameter | %1: | Logical axis number [-] | ||
| Logical axis number (P-AXIS-00016) of affected axis | ||||
| %2: | State [-] | |||
| Timestamp of the digital input terminal | ||||
| %3: | State [-] | |||
| Timestamp with shift times considered | ||||
| %4: | Lower limit value [-] | |||
| Smallest stored Distributed Clocks time | ||||
| %5: | Upper limit value [-] | |||
| Largest stored Distributed Clocks time | ||||
| Error type | 1, Error message from NC program. | |||
| 
 | ||||