ID 51049
| Monitoring levels in activated areas has to be identical. | ||||
| Description | Starting position: Several areas are active. Example with error: %area %Lsub_area_def_imcs N80 #CONTROL AREA END M29 %Lsub_area_def_mcs N80 #CONTROL AREA END M29 %main LL sub_area_def_imcs LL sub_area_def_mcs #CONTROL AREA ON ALL ; … M30 The two lines must be corrected, either both must contain MONITOR_LVL = "IMCS" or MONITOR_LVL = "MCS" . | |||
| Response | Class | 6 | Abrupt stop for all axes. | |
| Solution | Class | 6 | Check NC program | |
| Parameter | %1: | Current value [-] | ||
| Identification number of the control area | ||||
| %2: | Expected value [-] | |||
| Active monitoring level | ||||
| %3: | Current value [-] | |||
| Monitoring level of the areas | ||||
| Error type | 1, Error message from NC program. | |||
| 
 | ||||