ID 50989
| Filter is not active, because no filter order is set. | ||||
| Description | No filter order (P-AXIS-00587) was defined for the filter in the required axis. The filter in this axis was therefore deactivated. To activate the filter, at least the filter type and a filter order must be specified for this filter. | |||
| Response | Class | 2 | Warning. | |
| Solution | Class | 3 | Check and modify the parameterisation. Specify an order for the filter in the appropriate axis (order of axis-specific filter P-AXIS-00587 or alternative order in time P-AXIS-00591 or across all axes using #FILTER [ORDER=…]). | |
| Parameter | %1: | Logical axis number [-] | ||
| Logical axis number (P-AXIS-00016) of axis concerned. (Parameter is optional) | ||||
| Error type | 1, Error message from NC program. | |||
| 
 | ||||